Milk Checker MCM-5L
Milk Checker is a digital compact detector that detects bovine mastitis with extreme precision. Through a quick and simple test, Milk Checker is capable of detecting clinical and subclinical mastitis simultaneously within seconds in all four quarters of the udder. Made in Japan, Milk Checker utilizes the most advanced technology to produce reliable results, guaranteeing the health of your herd.Measurement principle
Milk checker is handy type instrument for cows to measure the electrical conductivity of milk in quarters of udder and to detect mastitis. When inflammation or other mammary disorders occurs, plasma constituents may exudate and cause changes in concentration of electrolytes contained in cow milk such as Na+, CL-, etc. A rise in sodium and chloride content results in increased electrical conductivity in the milk. Milk Checker is based on this principle and can detect abnormalities in the udders quickly and accurately by measuring electrical conductivity of milk.
Advantages
Fast and reliableAn innovative technology, Milk Checker is more reliable than other methods of mastitis detection. Unlike the complicated California Mastitis Test, which is subjective and requires mixing the milk with a solution, Milk Checker numerically displays results on digital display, with decimal precision, thus saving time and money.
Monitors your herd’s health
Milk Checker is an important in the management of herd. By using Milk Checker regularly throughout the lactation period, one can easily identify the infected cattle and separate them from the rest of herd. In addition, Milk Checker can also be used to determine the efficiency of antibiotic treatment.
Prevents outbreaks of clinical mastitis
Every year, mastitis outbreaks result in substantial losses for dairy farmers. Therefore, prevention is imperative. It is be able to detect infection at a preliminary stage, when it is still imperceptible. Thus, you avoid the high costs of veterinary treatment, antibiotics, and discarding milk and cattle, etc.
Quality
Milk Checker is a compliant device to Special disease medical guidelines by Mutual Aid Association of Veterinary Japan, as applicable electrical conductivity might be risk of mastitis infection in the quarter. Therefore, Milk Checker is favored mastitis detector in most countries with high quality control of milk such as Japan, Australia, and New Zealand.The guideline of electrical conductivity for confirmation on mastitisby Mutual Aid Association of Veterinary Japan
Absolute Conductivity | 6.2mS / cm or more | Abnormal milk |
Differential Conductivity | 0.5mS / cm or more | Infected |
Why New Milk Checker?
NEW Features !!- Sample storage capacity up to 500 samples
- Bluetooth® data transfer: suitable for data management by large farmers
- Automatically blinking for abnormal milk: Easy to get the result
- Temperature probe: accurate and stable data in different ambient and milk temperature.
Specification
Measuring Method | : Measurement of electrical conductivity |
Calculation | : Differential E.C. is calculated by microcomputer and automatically calibration. |
Display | : Backlight LCD |
Measurement Range | : 0 - 13mS/cm |
Accuracy | : 3% ± 1 digit |
Automatic Temperature Compensation | : +3 - 40°C (compensated at +25°C) |
Power Source | : Dry cell battery AA x 2 pcs. |
Power Consumption | : 140 mA (measuring and backlight on) |
Dimensions | : 91(w) × 149.5(H) × 118(D)mm |
Weight | : 320 g |
Data Communication | : Bluetooth® |
Real Time Clock | : IC module |
EEPROM | : Storage 500 data in device |
Introduction
What is mastitis??- inflammation f mammary gland in breast or udder.
- Due to bacterial infection via a damaged teat.
- Mastitis is classified by *Clinical Mastitis / *Subclinical Mastitis / *Chronic Mastitis
- Clinical and Chronic mastitis can be physical inspection in milk, but subclinical stage can not be detect by physical inspection, milk appears to be normal in subclinical stage.
What is Subclinical Mastitis?
![](https://www.arbrown.com/english/products/milk_test/digital_mastitis_detector/images/graf1.jpg)
Clinical mastitis can be easily detected because "kernels" are found in milk or various changes occur in udder. However it is very difficult to detect latent or subclinical mastitis by visual inspection.
- It is occur by 15-40 times more prevalent than clinical mastitis.
- It usually precedes clinical mastitis.
- It is of long duration.
- It causes reduction in milk production and also adversely affects milk quality. (W.N.Philpot)
ECONOMIC LOSS DUE TO MASTITIS
Decrease of milk quantity caused by subclinical mastitis occupies 70% of total economic loss due to mastitis. Without being aware this disease causes considerable loss to dairy farmers.![](https://www.arbrown.com/english/products/milk_test/digital_mastitis_detector/images/graf2.jpg)